![EXFO Power Blazer 88200NGE User Manual Download Page 362](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938362.webp)
Test Setup - Test Configurator, Timer, and System
352
88000 Series
Streams - Global
Addressing MAC/IP
indicates the source and destination MAC/IP
addresses for each stream. Tap on the
Addressing MAC/IP
button to
modify the customer addressing (see
MAC
and
IP
from the
MAC/IP/UDP
tab). When using
Provider Encapsulation
, the source
and destination addresses displayed are respectively EoE MAC for EoE
and B-MAC for PBB-TE.
Batch
button allows bulk configuration for stream addressing. Select
the check box of each configuration parameter that needs to be copied
and set its parameters. From
Apply To
, select all streams the copy
applies to and tap on the
Copy From
to proceed.
The following parameters are global for all streams.
Total TX Rate
indicates the percentage of the total line utilization
which is the TX rate sum of all enabled streams.
Link Capacity
indicates the total rate available for traffic generation.
Global Options
:
Rate Unit
choices are
%
(default),
Mbit/s
,
Gbit/s
,
frame/s
, and
IFG
.
QoS Metrics Tags Insertion
check box when selected (default)
automatically adds a stream analysis tag containing Jitter, Latency,
Throughput, and sequence tags in all frames that is generated.
Copy Stream
button allows copying the stream configuration to one or
several streams.
Select the stream number the configuration will be copied from.
From
To the following Streams
, select all streams that will inherit the
configuration from the selected stream. An orange background
represents a selected stream. A stream that is already enabled (Enable
TX) cannot be selected for copy.
Tap
Copy
to confirm the stream configuration for all selected streams.
Restore Default
button reverts the current test application to its default
factory settings.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...