Test Setup - Test Configurator, Timer, and System
Power Blazer
331
Signal
Note:
Frequency offset is not available when
Through
mode is selected.
Step Size (ppm)
allows setting the increment/decrement value (from
0.1 to the maximum offset) that will be used when changing the
frequency offset with the “+” or “-” button.
RX Frequency
Note:
The following RX Frequency information applies to serial interface only,
refer to
on page 216 for parallel interfaces.
E3
± 50 ppm
34368000 bit/s
DS3
44736000 bit/s
STS-1e/STM-0e
51840000 bit/s
E4
139264000 bit/s
STS-3e/STM-1e
155520000 bit/s
OC-1/STM-0
± 50 ppm
51840000 bit/s
OC-3/STM-1 155520000
bit/s
OC-12/STM-4 622080000
bit/s
OC-48/STM-16 2488320000
bit/s
OC-192/STM-64 9953280000
bit/s
OTU1
± 50 ppm
2666057143 bit/s
OTU2
± 50 ppm (Framed)
± 120 ppm (Unframed)
10709225316 bit/s
OTU1e
± 120 ppm
11049107143 bit/s
OTU2e 11095727848
bit/s
OTU1f 11270089286
bit/s
OTU2f 11317642405
bit/s
a.
The frequency offset range is guaranteed for a source signal at 0 ppm. In the event
that the source signal already has an offset, then the output signal may exhibit an
offset larger than the range specified.
Interface
Frequency Offset
a
Nominal Frequency
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...