![EXFO Power Blazer 88200NGE User Manual Download Page 393](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938393.webp)
Test Setup - Test Configurator, Timer, and System
Power Blazer
383
Wander
cTE Averaging Period (s)
defines the averaging period used to
calculate the constant Time Error (cTE) value over a specific period of
time:
Elapse time
(default),
100 s
,
500 s
,
1000 s
,
10000 s
.
dTE
H
Observation Period (s)
defines the observation period used for
qualifying the Time Error after High-Pass filtering 0.1 Hz:
100 s
,
500 s
,
1000 s
,
10000 s
(default).
Cable Delay Compensation (ns)
, available for time error
measurements, allows manual compensation of external cable delay
asymmetry: -
1000 ns
to
1000 ns
(
0 ns
by default).
The cable delay asymmetry is caused by the difference between the
length of the cable feeding the reference signal and the one feeding
the signal under test. For example to compensate for a cable delay of
-39 ns, enter this measured value as the
Cable Delay Compensation
:
-39 - (-39) = 0 ns
.
Duration
check box, when selected (cleared by default), allows
selecting/entering the test duration:
15 minutes
,
1/2/4/6/12/24/72
hours
, or
User Defined
(1 second up to 30 days depending on the
selected
Sampling Rate
).
Note:
Once the test completes (after the duration is reached or when manually
stopped), MTIE calculation may take some time depending on the test
duration and sampling rate used.
G.8261.1- PEC-Slave Frequency Case 3
X
-
G.8262- EEC Option 1- SyncE - Constant Temperature
X
X
G.8262- EEC Option 1- SyncE - Variable Temperature
X
-
G.8262- EEC Option 2- SyncE - Constant Temperature
X
X
G.8263- PEC-Slave Frequency - Constant Temperature
X
-
G.8263- PEC-Slave Frequency - Variable Temperature
X
-
G.8271.1- Dynamic Time Error
X
-
Mask
MTIE TDEV
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...