HYDRAULIC ATTACHMENT SYSTEM
Quick Connect Fittings (Auxiliary Hydraulic Circuit only)
2007 Carryall 295/295 SE & XRT 1550/1550 SE Gasoline, Diesel and IntelliTach M & S Manual
Page 16-25
16
QUICK CONNECT FITTINGS (AUXILIARY HYDRAULIC CIRCUIT ONLY)
QUICK CONNECT REMOVAL
1. Relieve pressure in hydraulic system.
See Relieving Hydraulic System Pressure on page 16-1.
2. Turn the key switch OFF and remove the key.
3. Set the joystick ON/OFF switch to OFF, remove driver seat and disable vehicle.
4. Disconnect the battery cables as instructed.
See WARNING “To avoid unintentionally starting...” in
General Warning, Section 1, Page 1-1.
5. Thoroughly clean the fittings and the area around them.
6. Mark hoses to ease reassembly and disconnect hoses from quick connect fittings.
See following NOTE.
Cover hoses and fittings to keep out debris.
NOTE:
Mark hoses for correct installation if factory markings are not found.
7. Remove the lock nut securing the quick connect fitting to the bracket
(Figure 16-36, Page 16-25)
.
QUICK CONNECT INSTALLATION
1. Reverse the removal procedure to install quick connect fittings. Tighten jam nuts to 30 ft-lb (41 N·m).
2. Match hose to fitting and connect hoses
(Figure 16-35, Page 16-24)
. Tighten fittings to 22 ft-lb (30 N·m).
Figure 16-36 Quick Connect Fitting Removal
Содержание IntelliTach XRT 1550
Страница 2: ......
Страница 22: ...1...
Страница 54: ...4...
Страница 60: ...5...
Страница 90: ...6...
Страница 114: ...8...
Страница 118: ...9...
Страница 196: ...11A...
Страница 290: ...11C...
Страница 468: ...13C...
Страница 490: ...14...
Страница 498: ...15...
Страница 548: ...16...
Страница 560: ...Club Car R NOTES...
Страница 561: ...Club Car R NOTES...
Страница 562: ...Club Car R NOTES...
Страница 563: ......