TROUBLESHOOTING AND ELECTRICAL SYSTEM: DIESEL VEHICLES
Troubleshooting Guide
2007 Carryall 295/295 SE & XRT 1550/1550 SE Gasoline, Diesel and IntelliTach M & S Manual
Page 11c-5
11C
Front differential does not engage front
wheels.
Failed front drive gearcase engagement
coil
Test Procedure 17 – Front Drive Gearcase
Coil on page 11c-37
Failed differential relay (early 2007) or
differential limit switch (late 2007)
Test Procedure 9 – Differential Relay on
page 11c-22 or Test Procedure 16 – Front
Differential Limit Switch on page 11c-36
Neutral switch failure (failed closed)
Test Procedure 14 – Neutral Switch
(Transmission) on page 11c-35
Failed front gearcase
See the Engines and Drivetrain
Components manual (CCI P/N
102396501).
Torque converter does not shift
smoothly.
Drive belt is worn, cracked, glazed, or
frayed
Drive Belt Removal on page 13c-28
Drive clutch malfunction
Drive Clutch Cleaning and Inspection on
page 13c-29
Driven clutch malfunction
Driven Clutch on page 13c-33
Battery discharged.
Loose alternator belt
See Alternator and V-belt Installation on
page 12c-15
Loose electrical connection(s)
Check for proper wiring and tighten any
loose connections. See Wiring Diagram
on page 11c-6.
Failed alternator
Test Procedure 18 – Alternator on
page 11c-37
Failed battery
Test Procedure 1 – Battery on
page 11c-13
60-amp fusible link failed
Test Procedure 19 – 60-Amp Fusible Link
on page 11c-38
Engine can be started while Forward/
Reverse handle is in the FOWARD or
REVERSE position.
Diode 3 failed closed
Test Procedure 13C – Diode 3 on wire 144
on page 11c-31
Hour meter adds increments with key
switch ON and engine not running.
Oil pressure switch failed open
See the Kubota D722 diesel engine
manual (CCI P/N 102615501).
Hour meter does not function.
Failed low oil warning light or oil pressure
sensor
Test Procedure 27 – Low Oil Warning
Light Circuit on page 11c-44
Oil pressure switch failed closed
See the Kubota D722 diesel engine
manual (CCI P/N 102615501).
Failed hour meter
Test Procedure 31 – Hour Meter on
page 11c-48
30-amp fuse (on w125) blows
repeatedly.
Diode 1 or diode 5 in wire harness failed
Test Procedure 13A – Diode 1 on wire 32
on page 11c-30 and Test Procedure 13E –
Diode 5 on wire 123 on page 11c-33
30-amp fuse (on w109) blows
repeatedly.
Diode 2 or diode 6 in wire harness failed
Test Procedure 13B – Diode 2 on wire 40
on page 11c-31 and Test Procedure 13F –
Diode 6 on wire 129 on page 11c-34
Bed lift does not function
Bed lift motor failed
Test Procedure 34 – Bed Lift Motor on
page 11c-51
Bed lift switch failed
Test Procedure 35 – Bed Lift Switch on
page 11c-52
Bed lift circuit breaker failed
Test Procedure 36 – Bed Lift Circuit
Breaker on page 11c-53
TROUBLESHOOTING GUIDE
SYMPTOM
POSSIBLE CAUSES
REFER TO
Содержание IntelliTach XRT 1550
Страница 2: ......
Страница 22: ...1...
Страница 54: ...4...
Страница 60: ...5...
Страница 90: ...6...
Страница 114: ...8...
Страница 118: ...9...
Страница 196: ...11A...
Страница 290: ...11C...
Страница 468: ...13C...
Страница 490: ...14...
Страница 498: ...15...
Страница 548: ...16...
Страница 560: ...Club Car R NOTES...
Страница 561: ...Club Car R NOTES...
Страница 562: ...Club Car R NOTES...
Страница 563: ......