TROUBLESHOOTING AND ELECTRICAL SYSTEM: HONDA POWERED GASOLINE VEHICLES
Test Procedures
2007 Carryall 295/295 SE & XRT 1550/1550 SE Gasoline, Diesel and IntelliTach M & S Manual
Page 11b-35
11B
7. The orange wire should remain disconnected for this step. Place the black probe of the multimeter on the
(3) terminal of the fuel gauge/hour meter and place the red (+) probe on the (1) terminal of the fuel gauge/
hour meter
(Figure 11b-29, Page 11b-35)
. The voltage reading should be the same as the full battery
voltage reading obtained in step 4. If the reading is incorrect, replace the fuel gauge/hour meter.
TEST PROCEDURE 26 – HOUR METER
See General Warning, Section 1, Page 1-1.
NOTE:
Keep the battery connected during this test procedure.
1. Place the Forward/Reverse handle in NEUTRAL. Chock the wheels.
2. Turn the key switch ON and record the current hour meter reading.
3. Turn the key switch to the START position and hold it until the engine is running smoothly. Release the
key and it will return to the ON position. The engine should idle.
4. Allow the engine to idle for at least 6 minutes (the meter records in 6-minute increments).
See following
DANGER.
ý
DANGER
• Do not operate vehicle in an enclosed area without proper ventilation. The engine produces
carbon monoxide, which is an odorless, deadly poison.
5. If the reading does not change after six minutes, check the low oil warning light and the oil pressure
switch.
See following NOTE. See also Test Procedure 22 – Low Oil Warning Light Circuit on
page 11b-32.
NOTE:
The hour meter is designed to record actual engine running time and will not start adding incre-
ments until the oil pressure switch has opened.
6. If the hour meter still does not function after the low oil warning light, oil pressure switch, and all of the
appropriate wires have been checked for continuity, replace the fuel gauge/hour meter.
Figure 11b-28 Fuel Gauge Voltage Test - Terminal 2
Figure 11b-29 Fuel Gauge Voltage Test - Terminal 1
2m
20
m
200
m
2k
200
200
200
200
20
2
200
m
500
20k
200k
2000
k
1000
OFF
WAVETEK
5XL
V
V
V
A
!
!
COM
200nA
MAX
1000 ---
750V
FUSED
1
3
2
18-GAUGE
BLUE WIRE
18-GAUGE BLACK
WIRE TO GROUND
Remove 18-gauge
orange wire.
18-GAUGE
WHITE WIRE
2m
20
m
200
m
2k
200
200
200
200
20
2
200
m
500
20k
200k
2000
k
1000
OFF
WAVETEK
5XL
V
V
V
A
!
!
COM
200nA
MAX
1000 ---
750V
FUSED
1
3
2
18-GAUGE
ORANGE
WIRE
Содержание IntelliTach XRT 1550
Страница 2: ......
Страница 22: ...1...
Страница 54: ...4...
Страница 60: ...5...
Страница 90: ...6...
Страница 114: ...8...
Страница 118: ...9...
Страница 196: ...11A...
Страница 290: ...11C...
Страница 468: ...13C...
Страница 490: ...14...
Страница 498: ...15...
Страница 548: ...16...
Страница 560: ...Club Car R NOTES...
Страница 561: ...Club Car R NOTES...
Страница 562: ...Club Car R NOTES...
Страница 563: ......