Messages
369
RIVAGE PM10 Operation Manual
Messages
Message
Meaning
[xx] connected
Device xx is connected.
[xx] disconnected!
Device xx is disconnected.
BAY LINK released.
A Bay Link was released.
This message appears if a bay link is released due to changes in
the SEL LINK settings.
Bay x does not exist.
You attempted to operate a non-existing bay (only for CS-R10-S).
Cannot add event! (event list full)
The maximum number of events (2000) allowed on the list has
been reached. You cannot add more events.
Cannot bookmark this popup
This popup window cannot be bookmarked.
Cannot close this page
This page cannot be closed.
Cannot edit overlay!
You cannot change the Overlay offset to a value outside the
specified range.
Cannot edit scene! (extracting scene data)
One of these messages will be displayed if you attempt to
perform an invalid operation during extraction of scene data, or if
you try to use the Global Paste function only on the standalone
control surface or only in PM10 Editor.
Cannot load file (extracting scene data)
Cannot recall! (extracting scene data)
Cannot save file (extracting scene data)
Cannot shutdown (extracting scene data)
Cannot store! (extracting scene data)
Cannot undo! (extracting scene data)
Cannot update! (extracting scene data)
Cannot mount!
Cannot load partial data now! (data in
console corrupt; only ALL file can be
loaded)
Partial data cannot be loaded.
Data inconsistency has occurred inside the console. Load entire
data all at once.
Cannot mount the plug-in. No DSP
resources available.
Additional plug-ins cannot be mounted due to insufficient DSP
resources.
Cannot mount! (plug-in too large for
selected location)
Plug-in failed to mount due to insufficient size of the slot.
Cannot open the bookmarked page
The bookmarked page failed to open.
Cannot paste!
The character string in the copy buffer is too long to be pasted.
Cannot perform this action! (scene data is
now being extracted)
One of these messages will be displayed if you attempt to
perform an invalid operation during extraction of scene data or
during the Global Paste operation.
Cannot perform this action! (global paste
in progress)
Cannot recall! (Internal error)
The scene cannot be recalled due to an internal error.
Cannot save now! (mixing data corrupt)
Control surface data is corrupt and cannot be saved.
To recover the data, access the DEVICE SYNC screen, and then re-
sync data in the DSP
→
CS sync direction. Alternatively, access the
SAVE/LOAD screen and load the control surface setting file.
Otherwise, initialize the control surface
Cannot Select for GLOBAL PASTE! (too
many scenes; max. 100)
You cannot select more than 100 scenes for the Global Paste
operation.
Cannot store! (too many scenes; max.
1000)
The scene cannot be stored because the maximum number
(1,000) of scenes that can be stored has already been reached.
Cannot sync in this direction! (DSP is
already online)
If the control surface or PM10 Editor is connected with the DSP
engine online, you will be unable to sync to transfer data to the
DSP engine.
Cannot sync in this direction! (mixing data
corrupt)
Data is corrupt. Syncing in this direction is not available.
If the control surface data is corrupt, syncing in the CS
→
DSP
direction is not available
If the DSP engine data is corrupt, syncing in the DSP
→
CS
direction is not available
Cannot trigger event! (event not found)
You cannot trigger any events from a device other than the
console, or non-existing events.
Cannot trigger event! (Event List can only
be operated from main console)
Cannot trigger event! (event list disabled)
If an event list is disabled, you cannot recall events.
Cannot undo! (Internal error)
The Undo operation failed due to an internal error.
Cannot update scene!
The scene failed to be stored due to an internal error.
Channel pair made
The channels are paired.
Channel pair made. (plug-ins and GEQ’s
have been unmounted)
The channels are paired. Inserted plug-ins and GEQ are now
unmounted.
Channel pair released
The channel pair was canceled.
Channel pair released. (plug-ins and GEQ’s
have been unmounted)
The channel pair was canceled. Inserted plug-ins and GEQ are
now unmounted.
Channel set to default
Channel data is reset to its default value.
Console initialization [XX] completed
The console initialization is complete.
Console local I/O firmware version
conflict! Try updating console firmware.
The system detected conflict in the firmware version of the
console’s built-in Local I/O section. Update the firmware for the
entire console, and then make sure that there will be no conflict.
Console local I/O model type conflict!
An internal error occurred on the console. Connections inside the
operating panel may be faulty. Please contact your Yamaha
dealer.
Console local I/O not responding!
Try updating console firmware.
The system cannot communicate with the console’s built-in Local
I/O section. Refer to the PM10 Firmware Update Guide (separate
document) to use PM10 FIRMWARE UPDATER for a recovery
operation.
Message
Meaning