CH Parameter
EQ
171
RIVAGE PM10 Operation Manual
■
Controlling the EQ via the OVERVIEW screen
1.
Press the [VIEW] key to access the OVERVIEW screen.
The EQ field shows the response of the EQ.
2.
Select the channel that you want to edit.
3.
Press the EQ field to access the HPF/EQ popup window.
If the HPF/EQ popup window (1ch) is displayed, you will be able to edit all of the EQ
parameters.
4.
Use the corresponding screen encoder or the [TOUCH AND TURN] knob to
adjust the EQ parameters.
HPF/EQ popup window (1CH)
This window enables you to edit all EQ parameters of the currently-selected channel. This is
convenient if you want to make detailed EQ settings for a specific channel.
1
HPF ON/OFF button
Switches the HPF on or off.
2
HPF FREQUENCY knob
Indicates the cutoff frequency of the HPF. Use the screen encoder to adjust the value.
3
HPF type select button
Enables you to set the HPF attenuation per octave to −6 dB/oct, −12 dB/oct, −18 dB/oct, or
−24 dB/oct.
4
LPF ON/OFF button
Switches the LPF on or off.
5
LPF FREQUENCY knob
Indicates the cutoff frequency of the LPF. Use the screen encoder to adjust the value.
6
LPF type select button
Enables you to set the LPF attenuation per octave to −6 dB/oct, or −12 dB/oct.
OVERVIEW screen
EQ field
B
E
D
F
G
H
C
9
8
1
4
7
2
3
5
6
*
A
@
)
!
^
$
#
%
(
&