GEQ/PEQ/Automixer
Graphic EQ, parametric EQ and Automixer
220
RIVAGE PM10 Operation Manual
■
Controlling a GEQ/PEQ via the SELECTED CHANNEL VIEW screen
1.
Select the channel that you want to operate.
2.
Press the [VIEW] key to access the SELECTED CHANNEL VIEW screen.
3.
Press the INSERT field to access the INSERT screen.
4.
Follow steps 4–8 on
.
Using the 31BandGEQ
1.
Follow steps 1–8 under “
Inserting a GEQ/PEQ into a channel
the 31BandGEQ into a channel.
The system displays the EDIT screen for the GEQ/PEQ that you inserted.
1
MOUNT GEQ/PEQ popup button
Press this button to access the MOUNT GEQ/PEQ popup window.
2
EQ graph
Indicates the approximate current response of the 31BandGEQ.
3
GEQ LINK button
Press this button to access the GEQ LINK window, in which you can link the GEQ of paired
channels.
NOTE
The GEQ LINK button appears only for paired GEQs.
4
FLAT button
Press this button to reset the GAIN parameters of all GEQ bands to 0 dB.
SELECTED CHANNEL VIEW screen
INSERT field
$
%
^
&
*
2
@
#
!
7
6
8
9
)
1
3
4
5