Maintenance
Adjusting the faders
350
RIVAGE PM10 Operation Manual
If POSITIONING calibration tab is selected:
For the specified faders in the Channel Strip section and Master section, the fader position will be
calibrated.
5.
Press the [SEL] key for each fader that you want to calibrate.
Faders for which a problem was detected in the fader settings at start-up will already be
selected.
6.
Press the START button.
7.
Each of the specified faders will move to the target positions in the following
sequence.
Manually move the faders to the correct positions.
1
−∞ dB (all the way down)
2
−20 dB
3
0 dB
4
+10 dB (all the way up)
8.
After you adjust the fader position, press the [NEXT] button.
The process will proceed to the next fader position.
9.
Repeat steps 7 and 8 to adjust the faders for positions
1
through
4
.
10.
When calibration is complete, press the FINISH button.
The calibration values will be saved in internal memory. If the [SEL] key lights and the color
bar becomes red, calibration has failed. Press the START button to perform calibration again.