Part Names & Functions
Rear panel of the control surface
69
RIVAGE PM10 Operation Manual
#
TO ENGINE OUT/IN connectors
These RJ-45 connectors allow the unit to be connected to a console network in a ring topology
via Ethernet cables (CAT5e or higher recommended).
NOTE
• Use an STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. Make sure
that the metal parts of the plugs are electrically connected to the STP cable’s shield by
conductive tape or comparable means.
• The use of Ethernet cables with Neutrik etherCON CAT5 compatible RJ-45 plugs is
recommended. Standard RJ45 plugs can also be used.
• Cable length can span up to 100 meters between devices. Maximum practical distance may
vary depending on the cable used.
$
ERR indicator
This indicator flashes red if an error occurs.
In such an event, please contact your Yamaha dealer.
%
LINK indicator
This indicator flashes or lights up, depending on the network status.
^
TX/RX indicators
The appropriate indicator flashes green when data is transmitted from (TX) or received at
(RX) the TO ENGINE OUT/IN connectors.
&
NETWORK connector
This RJ-45 connector allows the unit to be connected to a computer via an Ethernet cable
(CAT5e or higher recommended).
NOTE
• Use an STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. Make sure
that the metal parts of the plugs are electrically connected to the STP cable’s shield by
conductive tape or comparable means.
• The use of Ethernet cables with Neutrik etherCON CAT5 compatible RJ-45 plugs is
recommended. Standard RJ45 plugs can also be used.
• Cable length can span up to 100 meters between devices. Maximum practical distance may
vary depending on the cable used.
*
LINK/ACT indicator
This indicator flashes or lights up green, depending on the connection status.
(
Vent
The control surface is equipped with cooling fans. These vents let warm air out from the unit.
Please make sure that you do not block the vents with any object.
A
AC IN connectors
Use these sockets to connect the supplied power cords. First connect the AC power cords to
this unit, and then insert the power cord plugs into AC outlets.
Insert the cable plugs all the way until they lock in place securely. The supplied AC power
cords feature a V-lock mechanism via a latch, which prevents the power cords from
disconnecting accidentally.
Caution
Be sure to turn off the power to the unit before connecting or disconnecting the power cords.
To disconnect each power cord, remove it while pressing the latch
on the plug.
B
I/
P
(Power switches)
Toggle between power on (
I
) and off (
P
).
Green
(flashing)
The unit is preparing to connect to the console network. If it continues
flashing, the system is not functioning properly. If the problem persists after
you take the following actions, please contact your Yamaha dealer.
• Turn the power to the RIVAGE PM10 system off and then on.
• Make sure that the cables are connected properly.
• Make sure that the cables are securely inserted (locked in).
• Change to a different cable.
Green
(lit steadily)
The unit is connected to the console network properly.