Component Structure
I/O rack (RPio622)
9
RIVAGE PM10 Operation Manual
I/O rack (RPio622)
This is an I/O rack for input/output of analog audio signals and digital audio signals of various
formats including AES/EBU to and from the DSP engine via a TWINLANe network card installed
in HY card slot 1. Six RY card slots and two MY card slots allow the I/O structure to be configured
flexibly. Two power supply units are built-in, providing redundant power.
Front panel
About the HY card slots
HY card slot 1 of the I/O rack is only for a TWINLANe network card. HY card slot 2 can be used as
general-purpose I/O. HY card slot 1 is 256-in/out, and HY card slot 2 is 128-in/out.
Rear panel
* Support is planned in a future update.
10U size
Jack list
Jack
Connector
Number of jacks
WORD CLOCK IN
BNC
1*
WORD CLOCK OUT
BNC
1
NETWORK
etherCON CAT5
1*
FAULT OUTPUT
Euroblock 3P
1
AC INLET
V-Lock Type
2
Slot list
Slot
Number
RY CARD SLOT
6
MY CARD SLOT
2
HY CARD SLOT
2