Channel Job
About DCAs
203
RIVAGE PM10 Operation Manual
About DCAs
The RIVAGE PM10 system features 24 DCAs that enable you to control the level of multiple
channels simultaneously. It includes the following features:
• DCA1–24 can be used for all input channels and all output channels.
• Both input channels and output channels can be assigned to the same group at the same time.
• All channels assigned to a DCA can be cued simultaneously.
• You can monitor the corresponding DCA at unity gain (which is equivalent to the level obtained
when the DCA fader is set to 0 dB).
• All channels assigned to a DCA can be temporarily recalled (rolled out) on the panel and
controlled individually (DCA ROLL-OUT).
Assigning channels to a DCA
There are two ways to assign a channel to a DCA.
• You can select a specific DCA first and then specify the channels to be assigned to the group, or
• You can select specific channel and then specify a DCA to which it should be assigned.
NOTE
DCA settings are saved as part of the scene.
■
Selecting the channels that will belong to a specific DCA
1.
Press the CH JOB button on the menu bar, and then select DCA ASSIGN.
The DCA/MUTE ASSIGN window (ALL DCA tab) opens.
DCA/MUTE ASSIGN window (ALL DCA)
1
Tabs
Use these tabs to select the 1CH, ALL DCA, or ALL MUTE window.
Channel Job
8
5
1
3
4
6
2
7