System Setup
WORD CLOCK
123
RIVAGE PM10 Operation Manual
WORD CLOCK popup window (Master mode)
■
MASTER CLOCK SELECT field
1
Master clock frequency display
Indicates the frequency (44.1 kHz, 48 kHz, 88.2 kHz, or 96 kHz) of the currently-selected
master clock. If the unit is not syncing to the master clock, “UNLOCK” will appear.
2
Clock status display
Indicates the status of synchronization with the master clock for each clock source. Each
indicator is explained below.
• LOCK (light blue)
Indicates that a clock synchronized with the selected clock source is being input. If an
external device is connected to the corresponding connector or slot, it indicates that a clock
is being input or output properly between that device and the RIVAGE PM10 system. If the
sampling frequency is close, this status may be displayed even if not synchronized.
• LOCK, BUT NOT SYNC’ED (yellow)
A valid clock is being input, but is not synchronized with the selected clock source. If an
external device is connected to the corresponding connector, it indicates that a clock is not
being input or output properly between that device and the RIVAGE PM10 system.
• UNLOCK (red)
A valid clock is not being input. If an external device is connected to the corresponding
connector, a clock will not be input or output properly between that device and the RIVAGE
PM10 system.
• UNKNOWN (black)
This indicates that the clock status cannot be detected because no external device is
connected or because there is no valid clock input. You will be able to select this connector/
slot, but successful synchronization cannot occur until a valid connection is established.
NOTE
• If the indicator for the port selected as the clock source has turned light blue, and the clock
frequency appears in the upper left of the MASTER CLOCK SELECT field, this indicates that
the RIVAGE PM10 system is operating correctly with the new clock.
• If the indicator for the selected clock does not turn light blue, make sure that the external
device is correctly connected, and that the external device is set to transmit clock data.
• Noise may occur at the output jacks when the word clock setting is changed. To protect your
speaker system, be sure to turn down the power amp volume before changing the word clock
setting.
3
Master clock select buttons (Internal/External)
Use the buttons to select the clock source that you want to use as the word clock master from
the following options:
• 44.1 kHz
• 48 kHz
• 88.2 kHz
• 96 kHz
The internal clock of the DSP engine (sampling rate: 96 kHz, 88.2 kHz, 48 kHz or 44.1 kHz)
will be the clock source.
• WORD CLOCK IN
The word clock supplied from the WORD CLOCK IN jack on the rear panel of the master
DSP engine will be used as the clock source.
NOTE
If the unit is initialized to the factory default status, the word clock default value will be set to 96k.
2
3
1