System Setup
SYSTEM CONFIG
113
RIVAGE PM10 Operation Manual
6
Level meter
Indicates the output level of the signal after level adjustment.
7
Tabs
Switch the display in units of eight channels.
RY16-AE INPUT1-8/INPUT9-16
AES/EBU INPUT 1-8 of the control surface’s rear panel
1
Patch indication
Indicates the channel that is patched.
2
Level meter
Shows the input level.
3
SRC button
Switches the sampling rate converter on/off for each pair of channels.
4
Clock status indicator
Indicates the status of the input signal.
5
PHASE button
Switches the phase of the input signal.
NOTE
This is a parameter within the I/O rack. It is different than the Ф parameter within the channel
module of the control surface.
6
M/S button
Switches the M/S decoder on or off for each pair of channels.
7
S-GAIN knob
Adjusts the side gain of M/S.
8
Tabs
Switch the input and output display in units of eight channels.
8
1
3
6
7
5
4
2