Monitor
CUE
144
RIVAGE PM10 Operation Manual
The illustration on the right shows the priority
of the [CUE] keys.
After you have switched groups from lower to
upper levels, if you then defeat cue for the
upper group, the previous [CUE] key status of
the group immediately below will be restored.
For example, if you switch groups in the order
of OUTPUT CUE group
→
DCA CUE group
→
INPUT CUE group
→
Other CUE group,
you can then successively defeat the [CUE]
keys (CUE/KEY IN CUE buttons) to
successively restore the [CUE] key status of the
previously-selected group.
About CUE OPERATION mode in Cue mode
• CH (Channel) mode
This mode assumes only one operator will operate the system. You can specify the cue destination
(CUE A, B, and A+B) for each channel individually.
You can change this destination for each channel individually by holding down the [SHIFT] key and
pressing the desired [CUE] key. (A
→
B
→
A+B
→
A
→
B
→
…)
• BAY mode
This mode assumes two operators will operate the system. You can specify the cue destination (CUE
A and B) for each bay. For example, you can send the same channel signal from bay L to CUE B, and
bay C to CUE A.
NOTE
You can also set the mode in the OPERATION MODE field in the PREFERENCES popup window
(
).
Using the Cue function
This section explains how to use the [CUE] key of a desired channel or DCA to monitor the Cue
signal.
NOTE
Be aware that if you turn CUE INTERRUPTION off in the MONITOR SETTINGS popup window, the
cue signal will not be sent to the connected monitor speakers. However, the PHONES output jacks on
the front panel will always output cue signals regardless of the Monitor on/off setting. For details on the
Monitor function settings, refer to “
1.
Press the MONITOR button on the menu bar to access the MONITOR screen.
The CUE field on the MONITOR screen enables you to check the current cue settings, and
turn Cue on or off.
1
CUE popup button
Enables you to access the CUE popup window, in which you can make detailed cue settings.
Select CUE A or B as the control target, and set the parameters in the corresponding field.
2
CUE MODE buttons
Enable you to specify the operation mode when multiple [CUE] keys are on.
•
MIX CUE mode
............ All selected channels will be cue-monitored.
•
LAST CUE mode
.......... Only most recently selected channel will be cue-monitored.
Other CUE group
INPUT CUE group
DCA CUE group
OUTPUT CUE group
1
2
3
4
5
6
7