CH Parameter
DELAY
190
RIVAGE PM10 Operation Manual
DELAY SCALE popup window
You can select the delay scale from the following five options.
1
METER
The distance in meter, calculated as the speed of sound at an air temperature of 20 °C
(343.59m/s) × the delay time (seconds).
2
FEET
The distance in feet, calculated as the speed of sound at an air temperature of 20 °C (68 °F)
(1127.26 feet/s) × the delay time (seconds).
3
SAMPLE (number of samples)
The delay time is shown as the number of samples. If you change the sampling frequency on
which the RIVAGE PM10 system operates, the number of samples will change accordingly.
4
msec (milliseconds)
The delay time is shown in units of milliseconds.
5
FRAME
The delay time is shown in units of frames.
Use the six buttons located below the FRAME button to select the number of frames per
second.
6
CLOSE button
Closes the DELAY SCALE popup window.
DELAY TIME popup window
Using the ENTER & NEXT button enables you to set the delay time for each channel consecutively.
1
Channel /− buttons
The field indicates the currently-selected channel. Press the + button to select the next
channel. Press the − button to select the previous channel.
2
ENTER & NEXT button
Press this button to confirm the delay time setting, and then move to the next channel.
6
1
2
3
4
5
2
1