MIDI/GPI
Basic MIDI Settings
336
RIVAGE PM10 Operation Manual
MIDI/GP window (MIDI SETUP page)
1
PORT/CH field
Enables you to specify the settings for the channel that transmit/receive MIDI messages.
•
Tx CH
.............................Press this button to access a popup window, in which you can select
a MIDI channel that will transmit MIDI messages.
•
Rx CH
.............................Press this button to access a popup window, in which you can select
a MIDI channel that will receive MIDI messages.
NOTE
The MIDI port setting is fixed to CONSOLE.
2
PROGRAM CHANGE field
Enables you to switch MIDI Program Change message transmission and reception on or off.
•
Tx
....................................Switches Program Change transmission on or off.
•
Rx
....................................Switches Program Change reception on or off.
•
ECHO
.............................Switches on or off echo output of Program Change messages. (If this
function is on, Program Change messages received from an external
device will be retransmitted without modification.)
3
PROGRAM CHANGE MODE field
Enables you to select the Program Change transmit/receive mode.
•
SINGLE
..........................If this button is on, Program Changes will be transmitted and
received on a single MIDI channel (Single mode).
•
MULTI
............................If this button is on, Program Changes will be transmitted/received
on multiple MIDI channels (Multi mode).
•
OMNI
.............................If this button is on, Program Changes on all MIDI channels will be
received in Single mode. Multi mode transmission/reception and
Single mode transmission are disabled.
•
BANK
.............................If this button is on, Bank Select messages can be transmitted and
received in Single mode. (Bank Select messages switch the group of
Program Change messages to be used.)
4
CONTROL CHANGE field
Enables you to switch MIDI Control Change message transmission and reception on or off.
•
Tx
....................................Switches Control Change transmission on or off.
•
Rx
....................................Switches Control Change reception on or off.
•
ECHO
.............................Switches on or off echo output of Control Change messages. (If this
function is on, Control Change messages received from an external
device will be retransmitted without modification.)
5
OTHER COMMANDS (MTC/MMC) field
Switches on or off echo output of other MIDI messages. (If this function is on, other MIDI
messages received from an external device will be retransmitted without modification.)
4.
To specify the channel on which MIDI messages will be transmitted or received,
press the channel select popup button.
The MIDI SETUP popup window for selecting the channel will appear. Operations in this
window are the same for both transmission (Tx) and reception (Rx). This window includes the
following items.
1
CH field
Enables you to select the channel from CH1–CH16 that
will transmit or receive MIDI messages.
1
2
4
5
3
1