Plug-ins
Controlling the parameters of a plug-in
260
RIVAGE PM10 Operation Manual
9
GR/-10/-20/OFF switches
Select the signal that is monitored by the VU meters.
GR:
The amount of gain reduction is shown.
-10:
The signal with –10 dBu as 0 VU is shown.
-20:
The signal with –20 dBu as 0 VU is shown.
OFF:
The VU meter is off.
■
MBC4
This high-quality four-band compressor utilizes VCM technology and features a GUI that offers
outstanding operability and visibility. All advantages of the musical behavior of analog compressors
have been built into the gain reduction circuitry of the MBC4, allowing smooth control of dynamics
while retaining the overall image of the original sound. The sound image can also be visually
manipulated via a graphical display.
1
GAIN LINE
This red horizontal line indicates the GAIN parameter values for the corresponding band.
2
MAXIMUM GR GUIDELINE
This orange horizontal line indicates a guideline for the maximum gain reduction. This
amount is approximate, and does not necessarily show a precise maximum gain reduction
amount.
3
GR ZONE
This red area changes according to the gain reduction amount for the corresponding band.
4
CROSSOVER LINE
This vertical line indicates the crossover point for the corresponding band.
3
5
8
9
1
2
4
6
7