OPC UA communication
9.3 Using the S7-1500 as an OPC UA server
Communication
Function Manual, 05/2021, A5E03735815-AJ
267
System data type "OPC_UA_NodeId"
For the OPC UA basic data type "OpcUa_NodeId", please refer to the following table for the
meaning of the parameters. Use OPC_UA_NodeId for the identification of a node in the
OPC UA server.
Parameter
S7 data type
Meaning
NamespaceIndex
UINT
Namespace index of the node in the OPC UA server.
A node can, for example, be a tag.
Identifier
WSTRING[254]
The designation of the node (object or tag) depends
on the identifier type:
•
Numeric identifier: The node is labeled with a
number, for example "12345678".
•
String identifier: The node is labeled with a name,
for example "MyTag". No distinction is made be-
tween upper and lower case.
IdentifierType
UDINT
Type of identifier
•
0: Numeric identifier
•
1: String identifier
•
2: GUID
•
3: Opaque
System data type "OPC_UA_QualifiedName"
See the following table for the structure of the system data type "OPC_UA_QualifiedName":
Name
S7 data type
Meaning
NamespaceIndex UINT
The namespace index of the name.
Name
WSTRING[64]
Name of the node or tag.
UDT "Guid"
For the basic data type "Guid", create the following PLC data type. The default values used as
examples can also be set differently.
Figure 9-44 "Guid" UDT
Summary of Contents for SIMATIC ET 200AL
Page 2: ......
Page 143: ......
Page 218: ......
Page 250: ......
Page 296: ......
Page 337: ......
Page 365: ......
Page 392: ......
Page 419: ......
Page 451: ......
Page 483: ......
Page 597: ......
Page 648: ......
Page 702: ......
Page 739: ......
Page 781: ......
Page 804: ......
Page 828: ......
Page 853: ......
Page 880: ......
Page 906: ......
Page 996: ...Diagnostics ...
Page 1121: ......
Page 1565: ......