Interrupts/diagnostic alarms
5.3 Diagnostics alarms
IO-Link digital input module DI 16x24VDC 8xM12 (6ES7141-5AH00-0BL0)
Equipment Manual, 08/2021, A5E47926661-AB
19
5.3
Diagnostics alarms
For each diagnostic event, a diagnostics alarm is issued and the LED DIAG flashes red on the
digital input module. You can read out the diagnostics alarms, for example, from the status of
the IO-Link master. You can evaluate the error codes with the user program.
Table 5- 3
Diagnostics alarms, their meanings and corrective measures
Diagnostics alarm Error code Meaning
Remedy
Short-circuit
0x7710
Short-circuit of an encoder supply to
ground
Eliminate the short-circuit
Note
Short-circuit at the sensor supply
A short-circuit at the sensor supply can cause wire break diagnostics of the IO-Link Master.
The behavior depends on the technical specifications of the IO-Link Master used.