OPC UA communication
9.3 Using the S7-1500 as an OPC UA server
Communication
254
Function Manual, 05/2021, A5E03735815-AJ
5.
Change the name of the new server interface so that it is descriptive in your project.
The name should have the following structure according to Euromap 77:
"IMM_<Manufacturer>_<Serial number>".
The example uses the name "IMM_Manufacturer_01234".
6.
In the "Import XML file" field, select an XML file that describes an information model.
The "Using OPC UA companion specifications (Page 245)" section describes how to create
such an XML file with the SiOME tool.
The figure below shows a section from the information model:
"IMM_MANUFACTURER_0123456" an instance (use) of the type "IMM_MES_InterfaceType"
which was defined by Euromap 77 . "InjectionUnit_1" is an instance of the
"InjectionUnitType" type of Euromap 77.