OPC UA communication
9.3 Using the S7-1500 as an OPC UA server
Communication
Function Manual, 05/2021, A5E03735815-AJ
249
7.
Now import the namespace "http://www.euromap.org/euromap77/"
To do so, click the "Import XML" button again in the "Information model" area.
Select the file "Opc_Ua.EUROMAP77.NodeSet2.xml".
8.
Create your own namespace for your project.
To do this, right-click in the "Namespaces" area on "OPC UA Modelling Editor Project" or on
"Namespaces" and select "Add Namespace".
SiOME opens the "Add Namespace" dialog.
9.
Enter the name of a new namespace.
The "YourCompany.org" namespace is used in the example.
SiOME now also displays the new namespace:
Figure 9-28 Display of the namespace in SiOME
10.
Create an instance from the root object type IMM_MES_InterfaceType of the Companion
specification Euromap 77.
To do so, in the "Information model" area, right-click the "DeviceSet" directory and select
"Add Instance".
SiOME displays the "Add Instance" dialog.
11.
For "Name", enter a meaningful name for your instance.
In the example, enter "IMM_Manufacturer_01234".
For "TypeDefinition", select "IMM_MES_InterfaceType".
This object type is the root object type of Euromap 77: If you generate an instance of this
object type, then use the Euromap 77 once in the address space of your OPC UA server.
Summary of Contents for SIMATIC ET 200AL
Page 2: ......
Page 143: ......
Page 218: ......
Page 250: ......
Page 296: ......
Page 337: ......
Page 365: ......
Page 392: ......
Page 419: ......
Page 451: ......
Page 483: ......
Page 597: ......
Page 648: ......
Page 702: ......
Page 739: ......
Page 781: ......
Page 804: ......
Page 828: ......
Page 853: ......
Page 880: ......
Page 906: ......
Page 996: ...Diagnostics ...
Page 1121: ......
Page 1565: ......