IO-Link I/O modules
System Manual, 08/2021, A5E48755395-AB
15
Application planning
3
3.1
Hardware configuration
Basic configuration with IO-Link I/O modules
Connect the IO-Link I/O module to an IO-Link port of the master with an M12-A coded plug.
The maximum cable length between an IO-Link device and an IO-Link master is 20 m.
Power is supplied to the IO-Link I/O modules via the IO-Link master.
You can connect one IO-Link I/O module per IO-Link port to an IO-Link master.
For I/O modules with high power demand, an M12-L power connector is available for an
additional supply voltage.
You can find information on the maximum infeed current in the technical specifications of
the modules in the respective equipment manuals or on the Internet
https://support.industry.siemens.com/cs/ww/en/view/109742667
).