100
Memory Operation Data
Section 4-6
Note
During memory operation, PCU status is input for the axis that started opera-
tion or the actual moving axis/axes specified by the axis designation. For
details on which axis/axes status is input, refer to
8-1-2 Axis Designation and
Flags
.
4-6
Memory Operation Data
The memory operation data is used for setting the data for memory operation
commands output to the PCU. The memory operation data settings must be
made in the PCU’s internal memory before commands are sent.
When a memory operation command (START, INDEPENDENT START) is
sent to the PCU from the operating memory area, the PCU executes the com-
mand based on the memory operation data settings.
Settings for memory operation data can be saved to flash memory.
4-6-1
Outline
Memory operation data consists of the following six types of data. Settings for
this data can be written from the CPU Unit to the PCU using data transfer.
1,2,3...
1.
Positioning sequences
2.
Speeds
3.
Positions
4.
Acceleration times
5.
Deceleration times
6.
Dwell times
For details of memory operation and the correlation between the different
types of data, refer to
SECTION 8 Memory Operation
.
The address allocation of the memory operation data is shown in the following
tables. The addresses shown in the table are the PCU’s internal addresses.
When writing data, specify the destination address as appropriate. For details
on performing data transfer, refer to
SECTION 5 Transferring and Saving
Data
.
Input
(PCU
to CPU
Unit)
NC4
@
3
NC2
@
3
NC1
@
3
l+56
l+32
l+20
l+60
l+36
l+64
l+68
PCU sta-
tus data
Present
position
(rightmost)
Present
position (left-
most)
Indicates the present position
of the axes controlled by the
PCU. The position is indi-
cated for the range
–2,147,483,647 to
2,147,483,647 pulses as
signed 32-bit hexadecimal
data using two words.
Indicated range: 80000001 to
7FFFFFFF Hex
(–2,147,483,647 to
2,147,483,647)
NC4
@
3
NC2
@
3
NC1
@
3
l+57
l+33
l+21
l+61
l+37
l+65
l+69
NC4
@
3
NC2
@
3
NC1
@
3
l+58
l+34
l+22
l+62
l+38
l+66
l+70
Sequence
number
In memory operation, indi-
cates the number of the
sequence currently being
executed.
SECTION
8 Memory
Operation
NC4
@
3
NC2
@
3
NC1
@
3
l+59
l+35
l+23
l+63
l+39
l+67
l+71
Output code
(See note.)
Indicates the output code
when in memory operation.
I/O
Model
Words
Name
Operation
Reference
X axis Y axis Z axis U axis
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...