![Omron CS1W-213 - REV 02-2008 Operation Manual Download Page 105](http://html1.mh-extra.com/html/omron/cs1w-213-rev-02-2008/cs1w-213-rev-02-2008_operation-manual_742355105.webp)
80
Axis Parameter Area
Section 4-3
Bit 08 to 11: Origin Detection Method
This setting specifies the origin detection method.
Bit 12 to 15: Origin Search Direction
This setting specifies the direction for detecting the origin input signal during
an origin search.
4-3-3
Operation Modes
The four operation modes are described below. The following abbreviations
are used in the wiring diagrams:
DCRI: Error counter reset input
DCRO: Error counter reset output
IC:
Input common
OACI:
Origin adjustment command input
OACO: Origin adjustment command output
OPI:
Origin proximity input
OS:
Origin input signal
PCSI:
Positioning completed signal input
PCSO: Positioning completed signal output
2
Single-direction mode
Detects origin while operating in designated origin search direc-
tion. (Does not reverse.) Error stop at limit input for designated
origin search direction.
3
Reverse mode 3 (supported for unit version 2.2 or later)
Basic functions are the same as with reverse mode 2. When the
direction is reversed at the origin proximity input signal, however,
the origin search operation will continue at the origin search
proximity speed until the origin input signal. (In reverse mode 2,
when the direction is reversed at the origin proximity input signal,
operation continues by accelerating toward the origin search high
speed.) Use this mode to reduce shock to mechanical systems.
Setting
Explanation
0
Takes origin input signal after origin proximity input signal turns
ON (
↑
) and OFF (
↓
).
1
Takes origin input signal after origin proximity input signal turns
ON (
↑
).
2
Takes origin input signal without using origin proximity input sig-
nal.
3
Takes origin input signal after limit input signal turns ON (
↑
) and
OFF (
↓
), or OFF (
↓
), without using origin proximity input signal.
(Enabled only for single-direction mode.)
Setting
Explanation
12
Origin search direction
Use to specify the direction for detecting the origin input signal
during an origin search.
0: CW, 1: CCW
13
Origin search preset (supported for unit version 2.2 or later)
After the origin search has been executed and successfully com-
pleted, the present position can be set to any position.
0: Not set (default). Same function as previously.
1: Set. Set the position where the origin signal was detected to
any desired position. The desired position is set in advance in
the position parameter in the operating data area (for one axis,
words l + 8 and l + 9).
14 to 15
Not used.
Setting
Explanation
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...