127
Reading Data with the READ DATA Bit
Section 5-3
After the data reading operation has been completed, the Data Transferring
Flag (word n+8, bit 14) is turned from ON to OFF. If an error occurs during
data transfer, the Error Flag (word n+8, bit 12) will be turned ON and the error
code will be output to n+10 in the operating memory area. Check this error
code to determine the cause of the error and correct it.
5-3-4
Data Reading Program Example
In this example, speeds #0 and #1 written in
5-2 Writing Data with the WRITE
DATA Bit
are read. The conditions to be set are the same as those for the data
writing example. The beginning word of the DM Area, where the read data is
to be stored, is D00500.
CPU Unit
CIO Area
Operating memory area
Common parameters
Operating data area
READ DATA (200113)
Data transfer
PCU (NC413; unit number 0)
Data area
Speed #0
Speed #1