154
Origin Search Operation
Section 6-4
the input of an origin proximity input signal, positioning will be stopped by the
first origin input signal after the deceleration has been completed.
Note
During error counter reset output, if the origin input signal turns ON again, the
Servo Drive’s error counter reset function is deemed to have been used, and
the error counter reset output is turned OFF. In this case, the output time of
the error reset counter will be less than 20 ms.
Origin Detection Method: 0
When the deceleration time is short, such as in cases where positioning
begins from within the origin proximity area, an origin input signal will be
detected immediately after the falling edge of the origin proximity input signal.
Be sure that the origin proximity input signal dog is long enough (i.e., more
than the deceleration time).
Origin Detection Method: 1
If an origin proximity input signal is input during deceleration, the stop position
will vary according to the length of the deceleration time.
Origin
proximity
input signal
Pulse
output
Start
Stop
Optimum position for origin
proximity input signal OFF.
Stop
Start
Origin input
signal
(Z-phase
signal)
Origin
proximity
input signal
Pulse
output
Start
Stop
Origin input
signal
(Z-phase
signal)
(When the deceleration
time is long.)
(When the deceleration
time is short.)
Start
Stop
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...