![Omron CS1W-213 - REV 02-2008 Operation Manual Download Page 208](http://html1.mh-extra.com/html/omron/cs1w-213-rev-02-2008/cs1w-213-rev-02-2008_operation-manual_742355208.webp)
183
Direct Operation Timing Charts
Section 7-5
Example 2: Changing target position to absolute position at –10,000 pulses while moving to absolute
position at 10,000 pulses
Example 3: Moving to relative position at 10,000 pulses
Position (I+8, I+9)
Speed (I+10, I+11)
ABSOLUTE
MOVEMENT
(word n, bit 03)
Pulse output
Speed
Time
Positioning Completed
Flag (word n+8, bit 05)
Busy Flag
(word n+8, bit 13)
2710 Hex (10000)
3E8 Hex (1000)
FFFFD8F0 Hex (
−
10000)
3E8 Hex (1000)
Position (I+8, I+9)
Speed (I+10, I+11)
RELATIVE
MOVEMENT
(word n, bit 04)
Pulse output
Speed
Time
Positioning Completed
Flag (word n+8, bit 05)
Busy Flag
(word n+8, bit 13)
2710 Hex (10000)
3E8 Hex (1000)