322
Error Code Lists
Section 11-5
Positioning
sequences
Sequence data
error
3000
to
3099
One of the following errors occurred in the
positioning sequence:
The completion code is not in the range 0
to 6.
The initial speed number is not in the
range 00 to 99.
The acceleration time number is not in the
range 0 to 9.
The deceleration time number is not in the
range 0 to 9.
The target speed number is not in the
range 00 to 99.
The dwell time number is not in the range
00 to 19.
One of the following errors occurred in the
axis designation:
The Y, Z, or U axis was specified for a 1-
axis PCU.
The Z or U axis was specified for a 2-axis
PCU.
More than one axis is specified for inter-
rupt feeding or speed control, or all axis
designation settings are set to 0.
(The last two digits of the code indicate the
position data number (00 to 99) where the
error occurred.)
Transfer the data
again after
checking and
correcting it.
When this error
occurs during
data transfer, all
data (including
the data with the
error) specified
for transfer will
be lost.
All operating
axes will be
decelerated to a
stop.
Dwell times
Dwell time error
4001
to
4019
These codes indicate that a dwell time is
outside the settable range (0 to 9.99 s).
(The last two digits of the code indicate the
dwell time number (00 to 19) where the
error occurred.)
Item
Name
Code
Cause
Clearing
method
Operation after
error
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...