![Omron CS1W-213 - REV 02-2008 Operation Manual Download Page 349](http://html1.mh-extra.com/html/omron/cs1w-213-rev-02-2008/cs1w-213-rev-02-2008_operation-manual_742355349.webp)
324
Error Code Lists
Section 11-5
Software lim-
its (JOG)
Manual CW
software limit
5070
The CW software limit was exceeded dur-
ing JOG operation.
After executing
RELEASE PRO-
HIBIT/ERROR
RESET, move in
the CCW direc-
tion.
The axis that
exceeded the
software limit will
be decelerated
to a stop. Other
operating axes
will not be
affected.
Manual CCW
software limit
5071
The CCW software limit was exceeded
during JOG operation.
After executing
RELEASE PRO-
HIBIT/ERROR
RESET, move in
the CW direction.
Sensor inputs Emergency
stop input
6000
The axis was stopped by an emergency
stop signal input.
Start operation
again after clear-
ing the emer-
gency stop input
and executing
RELEASE PRO-
HIBIT/ERROR
RESET.
An emergency
stop will be per-
formed on the
affected axis.
Other operating
axes will not be
affected.
CW limit stop
6100
The axis was stopped by a CW limit input
signal.
Move in the
CCW direction
after executing
RELEASE PRO-
HIBIT/ERROR
RESET.
CCW limit stop
6101
The axis was stopped by a CCW limit
input signal.
Move in the CW
direction after
executing
RELEASE PRO-
HIBIT/ERROR
RESET.
Group
Name
Code
Cause
Clearing
method
Operation after
error
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...