267
Memory Operation
Section 10-2
Positions
Note
Addresses other than the above should be set to their default settings (0).
Acceleration and
Deceleration Times
The origin search acceleration and deceleration times will be used for acceler-
ation and deceleration and so this data needs to be set completely to the
default settings (0).
Dwell Times
Dwell times are not used in these programs, so this data area needs to be set
completely to the default settings (0).
Zones
Zones are not used in these programs, so this data area needs to be set com-
pletely to the default settings (0).
Address
Setting
Contents of setting
11F4
04B0
Position #0
1,200 pulses (4B0 Hex)
11F5
0000
11F6
03E8
Position #1
1,000 pulses (3E8 Hex)
11F7
0000
11F8
03E8
Position #2
1,000 pulses (3E8 Hex)
11F9
0000
11FA
03E8
Position #3
1,000 pulses (3E8 Hex)
11FB
0000
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...