209
Completion Codes
Section 8-5
Even if the completion code is continuous, operations can be executed in
which the positioning direction is reversed. In that event, the positioning will be
as follows regardless of the target speeds, absolute positions, or relative posi-
tions for the respective sequences.
If a dwell time (numbers 1 to 19) has been set, operation will be the same as
that for automatic completion, not continuous completion.
Example
With sequence # n (continuous) and sequence # n+1 (bank end), there will be
an immediate reversal when reversing from sequence # n to sequence # n+1,
with no acceleration or deceleration.
Speed
Sequence
#n
Sequence
#n+1
Time
Sequence
number
Sequence
Number Enable
Continuous completion
START
(See note.)
Note
If INDEPENDENT START is executed, a terminating com-
pletion, and not a continuous completion, will result.
Speed
Sequence
#n
Sequence
#n+1
Time
Sequence
number
Sequence
Number Enable
Continuous completion
START
(See note.)
Note
If a dwell time has been set, the position is executed and
then there is a pause for the duration of the dwell time
before the next positioning sequence (n+1) is executed.
Dwell time
CPU Unit to PCU
CPU Unit to PCU
Speed
Sequence
#n
Sequence
#n+1
Time
Immediate reversal
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...