Error Code Lists
Section 11-5
Common
parameters
Operating data
area designation
error
0010
The operating data area designa-
tion (m) is incorrect.
• Area designation: Set to a set-
ting other than 00, 0D, or 0E.
• Bank designation: Set to a set-
ting not in the range 00 to 0C,
when 0E is set for the area des-
ignation.
In this condition, only the data save
operations can be performed. In this
case, the PCU's axis parameters and
data are all returned to their default
values if the unit version of the PCU is
earlier than version 2.3. If the unit ver-
sion of the PCU is version 2.3 or later,
only parameters and data for which an
error has been detected will be
returned to their default values.
After correcting the common parame-
ters (refer to
SECTION 4
), reset the
power supply or restart the PCU.
Common
parameters
Operating data
area address des-
ignation error
0011
The designation of the beginning
word of the operating data area’s
address (m+1) is outside the setta-
ble range.
In this condition, only the data save
operations can be performed. In this
case, the PCU's axis parameters and
data are all returned to their default
values if the unit version of the PCU is
earlier than version 2.3. If the unit ver-
sion of the PCU is version 2.3 or later,
only parameters and data for which an
error has been detected will be
returned to their default values.
After correcting the common parame-
ters (refer to
SECTION 4
), reset the
power supply or restart the PCU.
Parameter desig-
nation error
0013
The axis parameter designation
(m+2) is not set to 00 or 01.
Alternatively, the combination of
settings for the number of unused
axes is incorrect.
Axis designation
error
0014
The axis parameter designation
(m+2) is set to 01, and 1 is set for
an axis not controlled by the PCU.
Axis parameters Response timeout 0020
The axis parameters set in the
CPU Unit could not be read to the
PCU.
Increase the cycle monitor time set
with CX-Programmer and either reset
the power supply or restart the PCU. If
this error occurs again, despite
increasing the cycle monitor time, it is
possible that there is a fault in the
PCU or somewhere in the PLC. Either
replace the whole PLC, or the PCU.
Group
Name
Code
Cause
Remedy
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...