![Omron CS1W-213 - REV 02-2008 Operation Manual Download Page 94](http://html1.mh-extra.com/html/omron/cs1w-213-rev-02-2008/cs1w-213-rev-02-2008_operation-manual_742355094.webp)
69
Common Parameter Area
Section 4-2
Memory Operation Data (refer to page 100)
Zone Data Area (refer to page 103)
4-2
Common Parameter Area
The common parameter settings determine the areas used to set the operat-
ing data (the operating data area) and axis parameters (the axis parameter
area) required for axis control. The common parameters must be set before
using the PCU.
PCU internal address
Name
Data size
X axis
Y axis
Z axis
U axis
1000
2000
3000
4000
Positioning
sequence num-
bers 0 to 99
3 words
112C
212C
312C
412C
Speed numbers 0
to 99
2 words
11F4
21F4
31F4
41F4
Position numbers
0 to 99
2 words
12BE
22BE
32BE
42BE
Acceleration time
numbers 1 to 9
2 words
12D2
22D2
32D2
42D2
Deceleration time
numbers 1 to 9
2 words
12E5
22E5
32E5
42E5
Dwell time num-
bers 1 to 19
1 word
PCU internal address
Name
Data size
X axis
Y axis
Z axis
U axis
12F8
22F8
32F8
42F8
Zone 0, CCW
2 words
12FA
22FA
32FA
42FA
Zone 0, CW
2 words
12FC
22FC
32FC
42FC
Zone 1, CCW
2 words
12FE
22FE
32FE
42FE
Zone 1, CW
2 words
1300
2300
3300
4300
Zone 2, CCW
2 words
1302
2302
3302
4302
Zone 2, CW
2 words
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...