![Omron CS1W-213 - REV 02-2008 Operation Manual Download Page 231](http://html1.mh-extra.com/html/omron/cs1w-213-rev-02-2008/cs1w-213-rev-02-2008_operation-manual_742355231.webp)
206
Positioning Sequences
Section 8-4
Operation Mode 2 or 3
The next operation is enabled when the designated dwell time elapses after
the Servo Drive’s positioning completed signal turns ON following the comple-
tion of pulse output.
8-4-7
Acceleration and Deceleration Time Numbers
These settings specify the acceleration and deceleration times for pulse out-
put, by setting acceleration/deceleration time numbers from 1 to 9 (Hex).
When either of these is set to “0,” the acceleration/deceleration time set in the
axis parameter area is used.
Speed
Sequence #n
Completion code:
automatic
Time
Positioning
Completed Flag
Busy Flag
Waiting for
memory operation
Sequence #n+1
Completion code:
automatic
The next sequence is
executed when the dwell
time elapses following the
completion of pulse output.
Speed
Servo Drive's
positioning
completed signal
Sequence #n
Completion code:
automatic
Time
Positioning
Completed Flag
Busy Flag
Waiting For
Memory Operation
Flag
Sequence #n+1
Completion code:
automatic
The next sequence is executed when
the dwell time elapses after the Servo
Drive's positioning completed signal
turns ON following the completion of
pulse output.
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...