162
Origin Search Operation
Section 6-4
Origin detection method
Origin search operation
3: Reverse mode 3
0: Takes origin signal after origin
proximity signal turns ON (
↑
) and
OFF (
↓
).
1: Takes origin signal after origin
proximity signal turns ON (
↑
).
Note
A limit signal is input and operation is stopped without deceleration.
Origin proximity input
signal
Origin input signal
Pulse output
Start
Stop
Stop
Start
CW limit (See note.)
Start Limit Stop
(Error code 6200)
▲
Origin search proximity speed
Note
A limit signal is input and operation is stopped without deceleration.
Origin proximity input
signal
Origin input signal
Pulse output
Start
Stop
Stop
Start
CW limit (See note.)
Start Limit Stop
(Error code 6200)