46
Connection Examples for Different Types of Motor Driver
Section 3-5
Parameter Setting Example
Note
“m” is the beginning DM word allocated when the unit number is set.
Origin Search Operation
The origin search operation is completed with the rising edge of the origin
input signal after the rising edge of the origin proximity input signal.
Word
Bits
Setting
Contents
m+4
00
0
CW/CCW output
01 to 03
0
---
04
0
Limit input: N.C. contact
05
1
Origin proximity input signal: N.O.
contact
06
1
Origin input signal: N.O. contact
07
0
Pulse output stopped with emergency
stop input signal.
08 to 15
0
---
m+5
00 to 03
0
Mode 0
04 to 07
0
Reverse mode 1
08 to 11
1
Takes origin input signal after origin
proximity input signal is received.
12 to 15
0
Search direction: CW
0
0
6
0
m+4
0
1
0
0
m+5
15
0
ORIGIN
SEARCH
Origin proximity
input signal
Origin input
signal
Pulse output
Busy Flag
Time
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...