![Omron CS1W-213 - REV 02-2008 Operation Manual Download Page 308](http://html1.mh-extra.com/html/omron/cs1w-213-rev-02-2008/cs1w-213-rev-02-2008_operation-manual_742355308.webp)
283
Direct Operation
Section 10-3
Operation Example
1,2,3...
1.
Set the number of inching pulses and the inching direction.
2.
When the INCH command switch is turned ON, the designated number of
pulses are output in the specified direction on the X axis, and the position-
ing is stopped.
(The pulse output speed at this time is the speed specified for direct oper-
ation.)
Setting the PCU
Unit number:
Unit #0
PCU used:
NC113
Data Memory Settings
Note
Set the operation mode (by setting an appropriate value for # in the table
above) according to the driver used.
Number of inching pulses
Inching direction switch
INCH command switch
Pulse output
Time
DM
Setting
Contents of setting
DM
Setting
Contents of setting
D20000
000D
Sets the operating data area
to D00500 (1F4 Hex)
onwards.
D20016
0000
Backlash compensation
(default setting)
D20001
01F4
D20017
0000
Backlash compensation
speed (default setting)
D20002
0001
Specifies that the axis param-
eters in the area starting from
D20004 will be used for all
axes.
D20018
0000
D20003
0000
Reserved
D20019
0000
Acceleration/Deceleration
curve: trapezoid (default set-
ting)
D20004
0060
I/O settings (default settings)
D20020
000A
Origin search acceleration
time (0 to maximum speed):
10 ms (A Hex)
D20005
000#
Operation mode (see note)
D20021
0000
D20006
01F4
Maximum speed: 500 pps
(1F4 Hex)
D20022
000A
Origin search acceleration
time (maximum speed to 0):
10 ms (A Hex)
D20007
0000
D20023
0000
D20008
0000
Initial speed (default setting)
D20024
270F
Positioning monitor time
(default setting)
D20009
0000
D20025
0001
CCW software limit (default
setting)
D20010
01F4
Origin search high speed:
500 pps (1F4 Hex)
D20026
C000
D20011
0000
D20027
FFFF
CW software limit (default
setting)
D20012
0064
Origin search proximity
speed: 100 pps (64 Hex)
D20028
3FFF
D20013
0000
D20029
0000
Reserved
D20014
0000
Origin compensation (default
setting)
D20030
0000
Reserved
D20015
0000
D20031
0000
Initial pulse designation
(default setting)
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...