286
Linear Interpolation
Section 10-4
Operation Example
In the following example, the program carries out an automatic interpolation
operation, then returns to the origin and stops.
When the operation start switch is turned ON, the following positioning is
automatically executed in the given order, using linear interpolation, and then
positioning is stopped.
(X,Y) = (5000, 1000)
→
(0, 2000)
→
(5000, 3000)
→
(0, 4000)
→
(5000, 5000)
→
(5000, 0)
→
(0, 0)
The interpolation speed at this time is 500 pps.
(Set the origin of both the X and Y axes beforehand to “0” by either conducting
an origin search or executing PRESENT POSITION PRESET).
Setting the PCU
Unit number:
Unit #0
PCU used:
NC213
X axis
Y axis