59
Servo Relay Unit
Section 3-7
3-6-2
CS1W-NC213/NC233 – X Axis Only (Unit Versions Earlier Than
2.1)
On PCUs with a unit version earlier than 2.1, unused axes require only the
emergency stop input signal to be wired.
Based on
Example 2: Mode 1 Connection
on page 47, the following example
shows the connections for the CS1W-NC213/NC233 when only the X axis
(and not the Y axis) is used. In this example, the limit input signals for both
axes are set to N.C. contacts. With the CS1W-NC413/NC433, if the Z axis is
used and the U axis is not used, the connection will be the same with X and Y
replaced by Z and U respectively.
When there is an unused axis, connect the emergency stop input signal (N.C.
contact) and the CW/CCW limit input signals (N.C./N.O. switchable) for that
axis so that they are ON. If the parameters are at their default settings, the
CW/CCW limit input signals are N.C. contact inputs and so connect an input
power supply and keep power ON.
If the emergency stop input signal and the CW/CCW limit input signals for an
unused axis are not ON, a sensor input error (error codes 6000, 6100, or
6101) will be generated for the axis, and the ERC and SENS indicators as
well as the LED indicator for the axis will light or flash. The used axis, how-
ever, will continue to operate normally even if an error is generated for the
unused axis.
Note
If the CW/CCW limit input signals for the unused axis are set to N.O contacts
using the parameter settings, it is not necessary to wire the CW/CCW limit
inputs. For details, refer to
4-3 Axis Parameter Area
.
3-7
Servo Relay Unit
• Wiring requirements can be reduced by connecting Servo Drives and
PCUs via a Servo Relay Unit, which provide a connector and a terminal
block in one Unit.
Position Control Unit
X axis (used)
Y axis
(not used; no wiring required)
X axis (used)
Y axis (not used)
Origin
proximity
input
signal
CCW limit
input signal
CW limit
input signal
Emergency
stop input
signal
N.C. contact
N.O. contact
Input
common
N.C. contact
N.C. contact
24 VDC
X axis (used)
Y axis (not used)
X axis (used)
Y axis (not used)
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...