220
Timing Chart for Memory Operation
Section 8-8
Note
If START is turned from OFF to ON when the Sequence Number Enable Bit is
OFF after a power-up or a restart, the sequence number error (error code
8101) will be generated.
When START is re-executed while the Sequence Number Enable Bit is OFF,
the sequence numbers executed will be the same as those for INDEPEN-
DENT START.
8-8-5
Timing of Data Changes during Memory Operation
It is possible to change positioning sequences and the data used in position-
ing sequences, such as speeds, positions, and acceleration times, during
memory operation. When performing positioning with the completion code set
to continuous, however, there will be a delay in the timing with which data
changes are reflected in operation.
When positioning sequences with completion codes set to continuous are
being executed continuously, the PCU reads up to 3 positioning sequences at
the start of memory operation. This means that if changes to data for a posi-
tioning sequence are not made during execution of the positioning sequence
at least 3 sequences before, these changes will not be reflected in operation.
Speed
Output pulses
Time
0000 Hex (0)
0000 Hex
(0)
0001 Hex
(0)
0002 Hex
(2)
0004 Hex
(4)
0002 Hex
(2)
0001 Hex
(0)
0000 Hex
(0)
0003 Hex
(3)
Sequence
#0
Sequence number
(word I+58, bit 00 to 15)
Waiting For Memory
Operation Flag
(word n+8, bit 04)
Busy Flag
(word n+8, bit 13)
Positioning Completed Flag
(word n+8, bit 05)
START
(word n, bit 01)
Sequence Number
Enable
(word n, bit 00)
Sequence number
(word n+16, bit 00 to 15)
Sequence
#1
Sequence
#2
Sequence
#3
Sequence
#4
Sequence
#0
Sequence
#1
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...