156
Origin Search Operation
Section 6-4
When the origin adjustment command (H-RET) is received by the Servo
Drive, the internal error counter is reset by the Z-phase of the encoder and
positioning stops.
The stop position is the same in Mode 1 and Mode 2. For an operation where
the start location of the origin search is different or where the deceleration
time is short, refer to the previously-described
Mode 1
. In Mode 3, if decelera-
tion is not completed when the origin proximity input signal is turned ON and
then turned OFF, an origin adjustment signal will be output after deceleration
is completed.
Origin Detection Method: 1
Deceleration starts on the rising edge of the origin proximity input signal, and
an origin adjustment command is output when deceleration is completed.
Origin adjustment
command output
Z-phase signal
Positioning
completed
Stops here
Servo Drive processing (with signal level ON condition set at 1)
Pulse
output
Time
Positioning
completed
input signal
Origin
proximity
input signal
Busy Flag
Origin
adjustment
command
output
Start
Stop
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...