284
Direct Operation
Section 10-3
Designation of the Operating Data Area
The operating data area is allocated to D00500 through D00523 by the data
memory settings. No prior settings are needed for the operating data area
because the data is set in the program.
Data Settings
Axis Parameters
The values for D20004 onwards are transferred when the power is turned ON
(or at restart).
Positioning Sequences
This data area is not used with direct operation. It should be left entirely at the
default settings (0).
Speeds
This data area is not used with direct operation. It should be left entirely at the
default settings (0).
Positions
This data area is not used with direct operation. It should be left entirely at the
default settings (0).
Acceleration and
Deceleration Times
This data area is not used with direct operation. It should be left entirely at the
default settings (0).
Dwell Times
Dwell times are not used in these programs, so this data area needs to be set
completely to the default settings (0).
Zones
Zones are not used in these programs, so this data area needs to be set com-
pletely to the default settings (0).
Program
W030 is used as a work word.
Summary of Contents for CS1W-213 - REV 02-2008
Page 2: ...CS1W NC113 213 413 133 233 433 Position Control Units Operation Manual Revised February 2008 ...
Page 3: ...iv ...
Page 13: ...xiv ...
Page 15: ...xvi ...
Page 19: ...xx ...
Page 43: ...18 Basic Operational Flow Section 2 1 ...
Page 87: ...62 Servo Relay Unit Section 3 7 ...
Page 199: ...174 Z phase Margin Section 6 8 ...
Page 217: ...192 Sample Program Section 7 7 ...
Page 285: ...260 Easy Backup Function Ver 2 0 or later Section 9 11 ...
Page 377: ...352 Common Parameter Area Appendix C ...