Two flags are available to indicate the status of the low-voltage detect system:
• The Low Voltage Detect Flag in the Low Voltage Status and Control 1 Register
(LVDSC1[LVDF]) operates in a level sensitive manner. LVDSC1[LVDF] is set
when the supply voltage falls below the selected trip point (VLVD).
LVDSC1[LVDF] is cleared by writing 1 to LVDSC1[LVDACK], but only if the
internal supply has returned above the trip point; otherwise, LVDSC1[LVDF]
remains set.
• The Low Voltage Warning Flag (LVWF) in the Low Voltage Status and Control 2
Register (LVDSC2[LVWF]) operates in a level sensitive manner. LVDSC2[LVWF]
is set when the supply voltage falls below the selected monitor trip point (VLVW).
LVDSC2[LVWF] is cleared by writing one to LVDSC2[LVWACK], but only if the
internal supply has returned above the trip point; otherwise, LVDSC2[LVWF]
remains set.
10.3.1 LVD reset operation
By setting LVDSC1[LVDRE], the LVD generates a reset upon detection of a low-voltage
condition. The low-voltage detection threshold is determined by LVDSC1[LVDV]. After
an LVD reset occurs, the LVD system holds the MCU in reset until the supply voltage
rises above this threshold. The LVD field in the SRS register of the RCM module
(RCM_SRS[LVD]) is set following an LVD or power-on reset.
10.3.2 LVD interrupt operation
By configuring the LVD circuit for interrupt operation (LVDSC1[LVDIE] set and
LVDSC1[LVDRE] clear), LVDSC1[LVDF] is set and an LVD interrupt request occurs
upon detection of a low voltage condition. LVDSC1[LVDF] is cleared by writing 1 to
LVDSC1[LVDACK].
10.3.3 Low-voltage warning (LVW) interrupt operation
The LVD system contains a Low-Voltage Warning Flag (LVWF) in the Low Voltage
Detect Status and Control 2 Register to indicate that the supply voltage is approaching,
but is above, the LVD voltage. The LVW also has an interrupt, which is enabled by
setting LVDSC2[LVWIE]. If enabled, an LVW interrupt request occurs when
LVDSC2[LVWF] is set. LVDSC2[LVWF] is cleared by writing 1 to
LVDSC2[LVWACK].
Low-voltage detect (LVD) system
MKW01Z128 MCU Reference Manual, Rev. 3, 04/2016
196
Freescale Semiconductor, Inc.
Summary of Contents for MKW01Z128
Page 7: ...MKW01xxRM Reference Manual Rev 3 04 2016 viii Freescale Semiconductor Inc...
Page 11: ...MKW01xxRM Reference Manual Rev 3 04 2016 xii Freescale Semiconductor Inc...
Page 133: ...MKW01Z128 MCU Reference Manual Rev 3 04 2016 2 Freescale Semiconductor Inc...
Page 233: ...Module clocks MKW01Z128 MCU Reference Manual Rev 3 04 2016 102 Freescale Semiconductor Inc...
Page 513: ...Interrupts MKW01Z128 MCU Reference Manual Rev 3 04 2016 382 Freescale Semiconductor Inc...
Page 633: ...CMP Trigger Mode MKW01Z128 MCU Reference Manual Rev 3 04 2016 502 Freescale Semiconductor Inc...