06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
109
Remote operator panel
Prerequisites
•
Device with electronics Gen. 3 (CPU board
A6621)
•
Drilling for connector mounting is available
•
Remote operator panel upgrade kit (article
number A8719)
The upgrade kit contains:
– Remote operator panel (article number
A8293)
– Internal cable (article number A8380)
Assembly of internal cable
(ALX 92x)
Tools
•
Cross-head screwdriver, small size
•
Hex socket wrench, size 4
Assembly
1. Remove the rear hood, see chapter
2. a) Drilling hole [242A] for connector moun-
ting is available: remove the cap.
b) Drilling hole for connector mounting is
not
available: drill the holes according to
3. Hold the connector from inside against the
side panel
The connector key [242B] must face the
built-in boards.
4. Push two screws (M2x16) from outside
through the side panel and the connector
holes. Mount lock washers and nuts on
each of the screws; tighten the nuts. Lock
each nut with a second nut [243, arrows].
Continue with
.
[240] Remote operator panel.
[241] Sizes and positions of drilling holes for the connector
mounting.
[242] Connector (A) for the remote operator panel at an ALX 92x
side panel (RH). Connector key position (B).
[243] Connector locked with a second nut (arrows) on each side.
19
±0,1
Ø12,70
-0,1
2x 2,50
Ø
A
B
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...