Characteristics HME PS 450
Inputs
Outputs
The total power of the outputs 2 and 4 may not exceed 250W!
Output 2: May only be activated by an I
2
C-bus-command!
AC output
The AC output of the HME power supply is internally protected together with
the power supply input by one single fuse (6.3A). The input current of the
HME power supply depends on the application as well as on the mains volt-
age. Therefore, there can be drawn a maximum current of 4A(AC) at 230V
and 1A(AC) at 110V from the power supply.
Characteristic
Value
Range of input voltage
100-240VAC
Admissible range of deviation
88-264VAC
Frequency range
60/50Hz
[Tab. 37] Characteristics of the input voltages.
Characteristic
Outputs
1
2
3
4
Output voltages (U
nom
)
5V
24V
24V
48V
Setting range
20-28V
Output currents (I
nom
)
2.7A
6.3A
1.5A
5.2A
Max. output currents
(I
peak
)
10A
7.3A
(t
≤
10s)
Pulsed output current
(I
puls
)
40A
(50% DC;
t
≤
0.5ms)
Tolerance
±2.5%
±5%
±10%
+5% / -10%
[Tab. 38] Characteristics of the output voltages.
Characteristic
AC output
Output voltage
max. 250V(AC)
Output current at 230VAC
max. 4A(AC)
Output current at 110VAC
max. 1A(AC)
[Tab. 39] Characteristics of the AC output.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...