06/16 Rev. 09
SERVICE MANUAL
Service Mechanics
DPM – PEM – ALX 92x
107
Assembling the ME500
Prerequisites:
– ME500
spare part kit
(installation instruc-
tion not included) A8328
– ME500
retrofitting kit
(installation
instruction included) A106954
1. Screw the power supply to the side panel
Attach the screws from the outside. Use
the same screws you disassembled before.
2. Screw the power supply with 1 screw
[236A] to the holding bracket inside of the
machine.
CAUTION! - The screw must not be lon-
ger than 5 mm (M3 x 5). Use one of the 2
screws contained in the kit for assembling
the not required mounting bracket [234D].
[234] Scope of delivery of ME500 spare part kit (A8328).
A
ME500 power supply
B
Cable strap (2x 100x2,5)
C
Cable holder
D
Mounting bracket (not required for installation in ALX 92x)
[235] Fastening of power supply (A) to side panel.
[236] Fastening of power supply (A) to the base plate.
A
B
C
D
A
B
A