05/16 Rev. 06
SERVICE MANUAL
Applicator Interface
ALX 92x – ALX 73x
Signal-Time-Diagrams
9
Reverse PEP
[3] Pattern of control signals over time for Reverse PEP applicators.
A
Duration is determined by label length and dispensing speed. „Airstream Support“ switching to low
means the label is dispensed.
B
Adjustable with
APPLICATOR PARA > Blow on time
.
C
Duration t is determined by the backwards movement of the. applicator. The application cycle ends
when the home position signal is high again
D
The output signal „Offline“ follows the input signal „Inhibit“.
E
The start signal is ignored because of the active „Inhibit“.
F
The end of „Cycle“ can be adjusted with
APPLICATOR PARA > Dwell time
(usually, this function sets the
end of the „Cylinder“ signal, in case of the Reverse PEP, „Cylinder“ stays active up to the next
start signal, what means that the dwell time is ignored).
A
B
D
C
E
F