05/16 Rev. 03
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
AP 4.4 – AP 5.4
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
54
The range of the value automatically measured by the gap detection can be
defined specifically for the label material. This allows materials with high-con-
trast proof points within the label to be processed, which would otherwise be
measured as 'false' gaps by the system. The corresponding setting value is
then equal to, or smaller than, the value measured at the actual gap.
Punch level
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
AP 4.4
AP 5.4
AP 5.6
Only if
PRINT PARAMETERS > Punch mode
= „Manual“.
xxx
Setting range: 0 to 255; Unit interval: 1
The value xxx stands for the current contrast within the photoelectric switch
of the material which has just been inserted. This serves to determine a
threshold value for the inserted material.
xxx = current measurement at the punch sensor
yyy = set threshold value
Example
Self-adhesive material with black bars lengthways across the label
•
Reading:
– Masking paper: 30
– Masking paper + label: 60
– Masking paper + label + black bars: 190
•
Setting value: 60
A setting value of 60 means that all readings over 60 are ignored, therefore
also the reading 190 at the black bar.
Punchlevel
Punch xxx Val yyy
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...